No 1, Tek 9 Road, Tinggi & New Tech Development Zone, Songshan Lake, Dongguan City, Provinsi Guangdong | sale@tonyhk.hk |
Detail produk:
Syarat-syarat pembayaran & pengiriman:
|
kekuasaan: | Elektronik | Nama Produk: | Peralatan Pengujian Laboratorium |
---|---|---|---|
Rentang pengukuran oksigen: | 0-25% | rentang pengukuran karbon dioksida: | 0-10% |
Cahaya Tinggi: | instrumen pengujian laboratorium,peralatan uji lab,Peralatan Pengujian Lab 5Kw |
Professional Power 5Kw Laboratory Testing Equipment With Radiation Intensity 100Kw / m2
Application:
Combustion product stream through the oxygen concentration of the oxygen consumption and calculate the heat release rate, heat release rate of the material is also the material properties of the combustion products of the combustion burner of the most important parameters, more accurately measure the material during combustion heat release rate, for predicting fire hazard prevention and fire-retardant treatment is extremely important.
Standards:
GB / T16172, ISO 5660-1 and -2, ASTM E 1354, ASTM E 1740, ASTM F 1550, ASTM D 5485, ASTM D 6113, NFPA 271, NFPA 264, CAN ULC 135, BS 476
Specification:
1. The radiation cone: heating power 5kw, radiation intensity: 100kw / m2, equipped with three thermocouples to measure the temperature.
2. Weighing equipment: imported high-precision electronic scales, weighing 500g, resolution 0.01g
3. The exhaust system: centrifugal fans, hoods, air intake and exhaust pipes as well as the composition of the orifice flowmeter
4. The gas sampling apparatus: sampling pump, particulate filter, dehumidification cold trap, emptying bypass coefficient, water filters, CO2 filter.
5. Gas analyzer and key components are imported.
6. With embedded computers and 8.4-inch LCD with TCP / IP and RS-232 communication interfaces choice
7. Oxygen measurement:
7.1 Measuring range: 0-25%
7.2 The signal output: 4-20mA;
7.3 The response time: ≤2S;
7.4 Ambient temperature: 0-45 ℃;
7.5 Relative humidity: <90% (non-condensing);
7.6 Linearity: <± 0.1% O2;
7.7 Zero drift: 0.05% O2 (one week);
7.8 Repeatability: <± 0.02% O2;
8. Carbon dioxide (CO2) measurements:
8.1 Measuring range: 0-10%
8.2 Repeatability: <± 1% Zero drift: ≤2% / week Span drift: ≤2% / week
8.3 Linearity deviation: <± 1%
8.4 Response Time: T90≤2 seconds
9. The data acquisition system to collect records oxygen concentration, carbon monoxide concentration test data, temperature, heat release rate, mass loss rate, it can save
Showroom:
Kontak Person: linmei
Tel: 86-13421721188
EN 71 Peralatan Uji Mudah-menyala untuk Pengujian Mudah-pakai Baterai untuk Flamabilitas
Peralatan Pengujian Flamabilitas Vertikal Untuk Uji Spread Flame Vertikal
Tester Flamabilitas Vertikal Multi-Purpose Tekstil dengan Kontrol Layar Sentuh
High Precision terbakar Peralatan Uji ASTM E 662 Bahan Solid untuk Smoke Density
9 KW Programmable Constant Temperature and Humidity Test Chamber
TNH-150A Programmable Temperature and Humidity Test Chamber 150 Liters
LED layar sentuh Pengendali Programmable Suhu Dan Kelembaban Test Chamber
Electronic 2 KW Temperature And Humidity Test Chamber 408 Liter
Universal Dual Arm Lab Testing Equipment / Tensile Strength Test Equipment
10 KN Electronic Servo MicroComputer Wood-based Panel Tensile Testing Machine
Laboratorium Universal Ganda Arm Tensile Strength Uji Mesin Komputer Servo
Big LCD Touch Screen Microcomputer Ganda Arm tarik Testing Equipment